Can one flat receive intercom calls from two entrances?
If a block has a street entrance and a courtyard entrance, both panels can be set up to call the same flat. One compatible indoor monitor is usually enough. Residents can also answer on a smartphone if the system supports an app and it has been set up for their flat.
One flat number at two doors
A courier arrives at the street entrance and dials 12. An hour later, visitors for the same resident dial 12 at the courtyard gate. Both calls reach the same monitor. If door release is configured for the calling entrance, the resident can let the courier in from the street and open the courtyard gate for the visitors.
The installer sets up two things: where calls from each panel go and which lock the resident can release. For example, the BAS‑IP guide for the BI‑FBI range (BI‑04FBI, BI‑08FBI and BI‑12FBI) specifies a different device number for each panel when the panels share a logical address. For other models, check the relevant installation guide. BAS‑IP panel setup guide.
Does every entrance need a call panel?
| Situation | What to allow for |
| Visitors arrive from the street or the courtyard | Fit panels at both entrances and route calls to the flats served by each door. |
| Only residents use the courtyard | A fob reader may be enough at that entrance. Visitors use the main door entry panel. |
| Visitors pass through a gate before reaching the block entrance | Decide whether they need to call at both points and who releases each door. |
| Flat numbers repeat across entrances | Check how the system distinguishes, for example, two flats numbered 12 and where a call from the shared gate will go. |
Adding an entrance to an existing system
Before ordering a second panel, note down the models of the existing panel and the devices in the flats. The installer can check how the new entrance will connect, whether the monitors can take calls from it and how the second lock will be controlled.
At handover, call the same test flat from both entrances. Check the sound and video, then release the door from the monitor and confirm that the correct lock opens. If residents will use an app, repeat the check on a smartphone.
Frequently asked questions
Does the flat need a second monitor?
One compatible monitor is usually enough, provided both panels can route calls to it.
Can the courtyard entrance call only some of the flats?
Yes, if the equipment supports call routing by entrance. The courtyard panel could serve only the flats in the part of the building reached through that door. Agree the list with the installer and check it at handover.